Test Code LMW-SPECTRUM Low Molecular Weight Heparin
Additional Codes
Mayo Access code: SHO8102
Performing Laboratory
Spectrum Laboratory
Specimen Requirements
Specimen Collection: Blood
Container(s): 3.2% Na Citrate Tube (blue top)
Preferred Volume to Collect: 2.7 mL (full 2.7 mL blue tube)
Minimum Volume to Collect: 1.8 mL (full 1.8 mL blue white tube)
Collection Instructions:
-
Sample should be collected 4 hours after subcutaneous injection.
- Specimen should be processed within 1 hour-See processing instructions below.
Specimen Processing and Transport Temperature
Processed Specimen: Platelet Poor Plasma
Centrifuge/Spin: Yes
Aliquot: Yes
Processing Instructions:
- Double spin plasma to create platelet poor sample.
- Separate plasma into 1 – 2 aliquots, minimum of 0.5 mL each.
- Freeze aliquots in plastic transport tubes immediately.
Transport Temperature:
- Ambient (up to 1 hour in whole blood state)
- Frozen (plasma only >1 hour)
Specimen Stability
Ambient: 1 Hour
Frozen: Aliquot and freeze platelet poor plasma within 1 hour of collection.
Laboratory Retention: 24 hours
Rejection Criteria: Hemolysis
Methodology
Chromogenic Based Assay
Reference Values
The therapeutic range for anticoagulation with LMW heparin has been reported to be 0.5-1.0 U/ml and the prophylactic range as 0.2-0.4 U/ml when measured by the anti-Xa method, with samples drawn 3-4 hours after SQ administration of either dalteparin or enoxaparin.
Test Classification and CPT Coding
CPT Code: 85520