Sign in →

Test Code CLFA Cryptococcus Antigen Screen with Titer, Spinal Fluid

Useful For

Aiding in the diagnosis of cryptococcosis

 

This test should not be performed as a screening procedure for the general population.

 

This test should not be used as a test of cure or to guide treatment decisions.

Reflex Tests

Test ID Reporting Name Available Separately Always Performed
CLFAT Cryptococcus Ag Titer, LFA, CSF Yes No

Testing Algorithm

If result is positive, Cryptococcus titer will be performed at an additional charge.

 

For more information see Meningitis/Encephalitis Panel Algorithm

Reporting Name

Cryptococcus Ag Screen w/Titer, CSF

Specimen Type

CSF


Specimen Required


Container/Tube: Sterile vial

Specimen Volume: 1 mL


Specimen Minimum Volume

0.5 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
CSF Refrigerated (preferred) 14 days
  Frozen  14 days

Reference Values

Negative

Reference values apply to all ages.

Day(s) Performed

Monday through Sunday

Report Available

Same day/1 to 2 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information

87899-Cryptococcus screen

87899-Cryptococcus titer (if appropriate)

LOINC Code Information

Test ID Test Order Name Order LOINC Value
CLFA Cryptococcus Ag Screen w/Titer, CSF 29896-8

 

Result ID Test Result Name Result LOINC Value
62074 Cryptococcus Ag Screen w/Titer, CSF 29896-8

Method Name

Lateral Flow Assay (LFA)

Forms

If not ordering electronically, complete, print, and send Infectious Disease Serology Test Request (T916) with the specimen.