Sign in →

Test Code C8FX C8 Complement, Functional, Serum

Reporting Name

C8 Complement, Functional, S

Useful For

Diagnosis of C8 deficiency

 

Investigation of a patient with an undetectable total hemolytic complement level

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Specimen Type

Serum


Ordering Guidance


The total complement assay (COM / Complement, Total, Serum) should be used as a screen for suspected complement deficiencies before ordering individual complement component assays. A deficiency of an individual component of the complement cascade will result in an undetectable total complement level.



Specimen Required


Patient Preparation: Fasting preferred

Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container/Tube: Plastic vial

Specimen Volume: 1 mL

Collection Instructions:

1. Immediately after specimen collection, place the tube on wet ice and allow specimen to clot.

2. Centrifuge at 4° C and aliquot serum into a plastic vial.

3. Within 30 minutes of centrifugation, freeze specimen. Specimen must be placed on dry ice if not frozen immediately.

NOTE: If a refrigerated centrifuge is not available, it is acceptable to use a room temperature centrifuge, provided the sample is kept on ice before centrifugation, and immediately afterward, the serum is aliquoted and frozen.


Specimen Minimum Volume

0.5 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Frozen 14 days

Reference Values

33-58 U/mL

Day(s) Performed

Monday through Friday

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information

86161

LOINC Code Information

Test ID Test Order Name Order LOINC Value
C8FX C8 Complement, Functional, S 50997-6

 

Result ID Test Result Name Result LOINC Value
C8FX C8 Complement, Functional, S 50997-6

Report Available

1 to 3 days

Method Name

Automated Liposome Lysis Assay